Switch-mode Power Supplies: 75-240 W

Efficient and customizable


Ask us about suitable power supply units!

A small, lightweight switching power supply unit that has a low power consumption in idle mode and a higher efficiency in operation is often sufficient. Our switched-mode power supply units can be used in the 85-264 VAC range on all standard mains voltages worldwide and are short-circuit proof.

A customized version of a power supply unit is also available on request, e.g. with a main switch, thermal fuse/switch or modified housing shape.

I need advice

A DC- or BLDC-motor only turns with a power supply unit

Specification for each power supply unit

Please request the technical specification for each power supply unit in order to compare it with all components of your planned drive system. If you cannot find the right power supply unit in the designs listed here, simply provide us with the specification you require. We can often meet customer-specific requirements.

Tell us your requirements for a power supply unit!

Specification for power supply unit SNT-G0250.24

An example of the technical data of a power supply unit

Input

  • Rated input voltage: 100-120 VAC and 200-240 VAC
  • Range of input voltage: 90-132 VAC and 180-264 VAC (ref. to "output load derating curve")
  • Frequency: 47-63 Hz
  • Power Factor: ≥ 0.45 @full load, 240 VAC
  • Input Current: 5.2 A / 115 VAC or 2.5 A / 230 VAC
  • Unload Power Consumption: ≤ 6 W
  • Inrush Current: COLD START ≤ 60 A max. @full load AC 230 V (after 1 mS)
  • Leakage Current: < 0.75 mA (240 VAC)

Output

  • Rated Voltage: 24 V DC
  • Voltage ADJ. Range: 20.4 V - 27.6 V
  • Current range: 10.5 A max.
  • Rated load: 252 W max.
  • Voltage Accuracy: ± 1 % @ 100-120 VAC and 200-240 VAC
  • Voltage Regulation: ± 0.5 % @ full load
  • Load Regulation: ± 0.5 %
  • Setup, raise time: 1300 ms, 50 ms / 230 VAC or 1300 ms, 50ms / 115 VAC @ full load
  • Hold-up time: ≥ 16 ms / 230 VAC, ≥ 12 ms / 115 VAC @ full load
  • Ripple & Noise Note.2: < 150 mVp-p
  • Efficiency(Typ.): ≥ 89 % @ full load, 230VAC

Protection

  • Over Load Protection: 110-150 % rated output power (protection type: auto recovery)
  • Over Voltage Protection: 28.8 ~ 33.6 V (protection type: auto recovery)
  • Short Circuit Protection: Protection type: auto recovery
  • Over Temperature Protection: Protection type: auto recovery

Environment

  • Operating Temperature: -30℃ ... +70℃ (ref. to "derating curve")
  • Cooling condition: Forced air cooling by built-in DC FAN
  • Storage Temp. Humidity: -40 ~ +85℃, 10 ~ 95 % RH
  • Temperature Coefficient: ±0.03 % / ℃ (0-50℃)
  • Working Humidity: 20~95 % RH, no condensation
  • Vibration: 10-500 Hz, 5G 10 min. / 1 cycle, 60 min. each along X,Y,Z axes

Safety & EMC

  • Safety standards: UL60950-1
  • Withstand voltage: I/P-O/P: 3.0 KVAC; I/P-FG: 1.5 KVAC; O/P-FG: 0.5 KVAC
  • Insulation resistance: ≥ 100 M Ohms / 500 VDC / 25℃ / 70% RH
  • EMI: EN55022 (CIPSR22), class B GB9254, class B EN55014,
  • EMS: Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A

Others

  • MTBF: ≥ 600 K hrs min. MIL-HDBK-217 F (25℃)
  • Dimension L*W*H: 215*115*30 mm
  • Weight: 0.79 kg/pc
  • Packaging: 21 pcs / box

Note to the specification

  1. All parameters NOT specially mentioned are measured at 240 VAC input, max. rated load and 25℃ of ambient temperature
  2. Ripple & Noise are measured at 20 MHz of bandwidth by using a 300mm twisted pair wire terminated with a 0.1 uF & 47 uF parallel capacitor

Mechanical specification

Derating - reduction of the output power

Derating means reducing the output power depending on the ambient conditions. Derating is therefore a recommended protective measure for electronic components and devices to protect them from high temperatures and prevent failures. The power reduction is specified for each power supply unit.


We do a lot to remain a strong partner in Drive Systems